Posts tagged ‘0x80AA’

DSP module test

Found in the net:
test voice driver and select 0 (for DSP slot in my case), 2 (DSP) then 16 (Display DSP Keepalive Status)
Result as below
DSP Keepalive Status Display:
=============================
DSP 1 is Alive, State: 4, Keepalive Sent: 130, Skip 131
DSP 2 is Alive, State: 4, Keepalive Sent: 97325, Skip 97329
DSP 3 is Alive, State: 4, Keepalive Sent: 97326, Skip 97328
DSP 4 Not Exist

2011/10/17 at 16:00 Leave a comment

Another DSP issue and error 0x80AA

I had to solve another problem with switching congestion equipement.
Again
Cause i = 0x80AA - Switching equipment congestion
However dspware version from “show voice dsp detail” was OK I tried:
test dsp device 0 all reset but it hasn’t changed my status. Resetting router aka reload and no change at all.
What I found was here:
router# Show voice dsp group all
DSP groups on slot 0:
dsp 1:
State: FAIL, firmware: 23.8.0
Max signal/voice channel: 16/16
Max credits: 240
num_of_sig_chnls_allocated: 8
Transcoding channels allocated: 0
Group: FLEX_GROUP_VOICE, complexity: FLEX
Shared credits: 240, reserved credits: 0
Signaling channels allocated: 8
Voice channels allocated: 0
Credits used: 0

dsp 2:
State: UP, firmware: 23.8.0
Max signal/voice channel: 16/16
Max credits: 240
num_of_sig_chnls_allocated: 0
Transcoding channels allocated: 0
Group: FLEX_GROUP_VOICE, complexity: FLEX
Shared credits: 240, reserved credits: 0
Signaling channels allocated: 0
Voice channels allocated: 0
Credits used: 0

Another time another DSP module to replace.

2011/10/17 at 15:38 Leave a comment

DSP issue and switching equipment congestion

A few weeks ago I faced an issue with DSP module. I was looking for a solution but there was a poor description in the network. Even Cisco error decoder hadn’t help at all. I hope this will help someone.
The problem waswith calls establishing. Phones were calling but no voice channel was created. In logs just short info.
Cause i = 0x80AA - Switching equipment congestion
I checked translation-rules, dial-peers etc. but when no changes have been done it wouldn’t be so simple. Some more discoveries and diagnostic as below:
Sh voice dsp detailed
*
*
Warning! DSPs1, in slot 0 are using non-default firmware from flash:
This is not recommended, the default version is 23.8.0

----------------------------FLEX VOICE CARD 0 ------------------------------
*DSP VOICE CHANNELS*

CURR STATE : (busy)inuse (b-out)busy out (bpend)busyout pending
LEGEND : (bad)bad (shut)shutdown (dpend)download pending

DSP DSP DSPWARE CURR BOOT PAK TX/RX
TYPE NUM CH CODEC VERSION STATE STATE RST AI VOICEPORT TS ABRT PACK COUNT
===== === == ========= ========== ===== ======= === == ========= == ==== ============
C5510 001 01 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 02 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 03 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 04 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 05 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 06 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 07 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 08 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 09 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 10 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 11 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 12 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 13 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 14 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 15 None 0.0.0 bad idle 1 0 0 0/0
C5510 001 16 None 0.0.0 bad idle 1 0 0 0/0
C5510 002 01 None 23.8.0 idle idle 1 0 0 0/0
C5510 002 02 None 23.8.0 idle idle 1 0 0 0/0
C5510 002 03 None 23.8.0 idle idle 1 0 0 0/0
C5510 002 04 None 23.8.0 idle idle 1 0 0 0/0
C5510 002 05 None 23.8.0 idle idle 1 0 0 0/0
C5510 002 06 None 23.8.0 idle idle 1 0 0 0/0
C5510 002 07 None 23.8.0 idle idle 1 0 0 0/0
C5510 002 08 None 23.8.0 idle idle 1 0 0 0/0

Difference between DSP NUM 1 and 2 shows that number 1 was broken. Fast change corrected and issue and all came back to normal work.

2011/10/07 at 09:52 Leave a comment


Calendar

May 2024
M T W T F S S
 12345
6789101112
13141516171819
20212223242526
2728293031  

Flags